Heat exchanger suite (HExS) version history
HExS – 3.0.0.0
Software licensing on new activation server
Update to ACHex
Minor update to results interface
Bug fix in export feature to .csv file
Update to HCHex
Bug fix affecting calculating unknown flow rate.
Added input validation error if the average diameter of helix is greater than the inside diameter of the outer cylinder
Added the ability to adjust the gap between the tube and the outer cylinder wall
Added the ability to adjust the gap between the tube and the core tube (for core tube models)
Update to CnD
Update report view for engineering datasheet generator
HExS – 2.0.0.5
Update to HCHex
- Added support for no core tube design
- Allow the calculation of core tube diameter when Shell inside diameter is defined
- Allow the calculation of Shell inside diameter when core tube diameter is defined
- Allow the calculation of both core tube diameter and Shell inside diameter
- Added new graphics
- Updated summary screens
HExS – 2.0.0.4
Update to DHex
- Maintenance release addressing
fixed bug to address failing to calculate the thermal capacity ratio
fixed bug to address failing to calculate the number of transfer unit
fixed bug to address failing to calculate pressure drop in annulus side
Update to S&THex
- Maintenance release
Added error check in physical properties import feature
HExS – 2.0.0.3
Update to ACHex
- Added condensing service – heat transfer coefficient is required when this service is in use.
only total condensation is currently supported - Added support for subcooling when condensing service is in use
- Results interface now can be maximized to fill screen
- Added water and steam properties
HExS – v2.0.0.2
Update to HCHex
- Introduced latent heat input on shell side and tube side
- Added support for phase change.
- Calculate both inlet flow rates when heat duty and temperatures are specified
HExS – v2.0.0.1
Update to DHex
- Added use hydraulic diameter for nusselt number calculation. This feature can be accessed through the software setting screen
- Minor fixes to interface
HExS – v2.0.0.0
Update to S&THex
- Update error log viewer, the software will now issue messages in the error log that
include the following types:
ERROR: This type of messages is used for errors in input or results, the software will stop until errors are fixed by the user
WARNING: This type of message is used for warning when parameters are exceeded, the software will continue buy some results may be invalid
MESSAGE: This type of message is used for general software informative messages
INFO: This type of message is used to provide additional information and guidance during operation
New Features: - Added kern tube counts
- Automate multiple cases by simply setting the changing parameters and allowing the software to iterate through these parameters and generate final results.
- Iterate through kern tube counts using the multiple cases feature
Automated mode for multiple case simulation: instead of manually changing values to add a case, this mode
will do the exact without user intervention. The manual mode is still avialable too.
You can now perform a simulation study by changing any of the parameters under the Study scenarios below:
Study parameters 1:
Tube outer diameter, Tube number of passes, Tube length, Number of tubes, Baffle spacing
Study parameters 2:
Uses kern tube counts to iterated between Shell diameters to obtain the number of tubes for a given number of passes.
User can set the study parameters and the software will automate the calculation steps and add the final result to summary screen
where the changes between each can can be detected.
This case study mode will automate the manual input for trial and error to optimise results.
HExS – v1.0.0.1
correct a bug in warning messages for P Props physical properties database
HExS – v1.0.0.0
First public release